Extraction of absolute water level in the Florida Everglades using TanDEM-X bistatic science phase observations with a large perpendicular baseline

Sang Hoon Hong, Shimon Wdowinski, Sang Wan Kim

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

1 Scopus citations

Abstract

High spatial resolution maps of relative water level changes in wetlands environment have been successfully generated using spaceborne interferometric synthetic aperture radar (InSAR) techniques. However, the wetland InSAR application has limited hydrological monitoring application, because it estimates water level changes not absolute water levels, which are used by hydrologists. TanDEM-X bistatic observations provide simultaneous phase measurements of water surfaces with a two-satellite constellation without temporal decorrelation. In this study, the TanDEM-X bistatic science phase observations with very large baseline (> 1.3 km) geometric configuration were evaluated to extract absolute water levels of the Everglades wetland in south Florida, U.S.A. Thanks to the large perpendicular baseline, spatial variation of water level surfaces with extremely low slope were estimated. We processed two datasets of TanDEM-X bistatic observations acquired on August 26 and 31, 2015. The perpendicular baselines are 1.43 km and 1.36 km and the ambiguity heights were calculated as 3.61 m and 3.90 m in each interferometric pair. The estimated absolute water level maps with 3.6 m and 7.4 m pixel spacing in range and azimuth directions (multilook factor of 4), respectively, show vast detailed variation of the water surfaces for each acquisition date. Hourly water level measurements obtained by stage stations, which are provided by the Everglades Depth Estimation Network (EDEN), were used for verifying the estimated absolute water levels. Some of stage stations, which are located in low interferometric coherence areas, such as dense vegetated and tree areas, were considered as outliers and were excluded from the comparison. The verification results show very good agreements (code of determination > 0.95) between the TanDEM-X derived absolute water levels and the stage station measurements. The root mean square error (RMSE) between the TanDEM-X results and stage records for the two datasets were 0.77 m and 0.66 m. Although, TanDEM-X bistatic observations have no temporal baseline, there are severe volume decorrelations over various tree types due to the very large perpendicular baseline. The TanDEM-L mission with longer wavelength of radar signal will enable us to generate more coherent interferometric phase observations over wetlands and, consequently, generate improved absolute water level maps.

Original languageEnglish
Title of host publicationEUSAR 2021 - 13th European Conference on Synthetic Aperture Radar, Proceedings
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages643-645
Number of pages3
ISBN (Electronic)9783800754571
StatePublished - 2021
Event13th European Conference on Synthetic Aperture Radar, EUSAR 2021 - Virtual, Online, Germany
Duration: 29 Mar 20211 Apr 2021

Publication series

NameProceedings of the European Conference on Synthetic Aperture Radar, EUSAR
Volume2021-March
ISSN (Print)2197-4403

Conference

Conference13th European Conference on Synthetic Aperture Radar, EUSAR 2021
Country/TerritoryGermany
CityVirtual, Online
Period29/03/211/04/21

Keywords

  • Everglades
  • Perpendicular baseline
  • TanDEM-X
  • TanDEM-X science phase
  • Water level
  • Wetland

Fingerprint

Dive into the research topics of 'Extraction of absolute water level in the Florida Everglades using TanDEM-X bistatic science phase observations with a large perpendicular baseline'. Together they form a unique fingerprint.

Cite this